About Us

Executive Editor:
Publishing house "Academy of Natural History"

Editorial Board:
Asgarov S. (Azerbaijan), Alakbarov M. (Azerbaijan), Aliev Z. (Azerbaijan), Babayev N. (Uzbekistan), Chiladze G. (Georgia), Datskovsky I. (Israel), Garbuz I. (Moldova), Gleizer S. (Germany), Ershina A. (Kazakhstan), Kobzev D. (Switzerland), Kohl O. (Germany), Ktshanyan M. (Armenia), Lande D. (Ukraine), Ledvanov M. (Russia), Makats V. (Ukraine), Miletic L. (Serbia), Moskovkin V. (Ukraine), Murzagaliyeva A. (Kazakhstan), Novikov A. (Ukraine), Rahimov R. (Uzbekistan), Romanchuk A. (Ukraine), Shamshiev B. (Kyrgyzstan), Usheva M. (Bulgaria), Vasileva M. (Bulgar).

Additional Information

Authors

Login to Personal account

Home / Issues / № 5, 2016

Medical sciences

REASONS FOR BREACH OF FIXING NON-REMOVABLE DENTURES
Mihalchenko D.V., Sirak S.V., Zhidovinov A.V., Matveev S.V.
Today in prosthetic dentistry is actively improved treatments using non-removable prosthetic. However, statistics show that when used complication rate remains high enough - figures premature disruption fixation range from 2% to 50%, and the development of caries in abutment teeth is from 23% to 50% of the total number of complications. [5] Many scientists who study the causes of unsuccessful outcomes of treatment non-removable prosthetic designs have come to the conclusion that this contributes to a large number of factors: selection and use of fixing material, the extent and quality of the preparation of the tooth surface, the violation of fit, the development of caries process after prosthetic fixation probability rastsementirovki. [5,6]

As a rule, the violation is caused by atrophy of the fixation of bone tissue under the prosthesis as the prosthesis manufactured by a cast compression, when applying it on the jaw fixes mucosa in a choked condition that impairs the blood and lymph circulation, leads to the development of inflammatory processes, and subsequently - to atrophic processes. Chewing pressure sensed by the mucous membrane, fixed prosthesis is physiological conditions, exacerbating these phenomena.

The cause is the fixing violations and improper preparation of teeth to prepare the surface for the design of fixing.

The quality of fit, in addition to the characteristics of the prepared tooth surface, influences the material to fix the crown and its stability in the tooth system - cement - the crown.

Common to all is the presence of orthopedic structures between the metal and tooth tissue gap, equal 30-50mkm. An important requirement for materials for permanent fixation is possible to obtain a thin (25 um) cement film that can fill the space between the surface of the tooth stump and the crown and ensure minimal contact with the fixing cement oral fluid. Working dental cement also affects the film thickness. For a long time (2-3 minutes) provides a greater flow of material, preferred for accurate fixation of orthopedic structures. Important characteristics for the fixing material is compressive strength, can withstand chewing pressure, solubility in the oral fluid, adhesion to hard tissues of the tooth, and others.

Another feature is the inherent high mechanical strength within time and multidirectional loads encountered in the mouth. This shear stress, bending, tearing, stretching and twisting. The coefficient of thermal expansion of the material in the manufacture of non-removable prosthetic teeth must match the CTE. A lot of importance is the constancy of the volume; good compatibility with tooth tissues, metals, plastics, porcelain, zirconia and alumina on the physical and mechanical characteristics; the absence of pulp irritation, etc.

The nomenclature list of tools and materials developed by the International Standards Organization (ISO), defined the technical requirements for materials for fixing. They are shown in Table 1. [6]

Table 1. Specifications for the materials to fix (for ISO)

Physical Properties Indicators

indicators

Film thickness

max 25 25 microns

The compressive  strength

min 65 MPa

Indicator solubility and disintegration

max 0,2%

Working time

min 2,0 minutes

Curing time

max 7,5 minutes

In determining the physical and mechanical properties of dental cements pay special attention to the definition of the thickness of the temporary cement film that gives an indication of marginal adaptation abutments, awareness of the thickness of the film is also a very important factor for the prevention of occlusive disorders, especially in the case of prosthesis on implnatah. The film thickness for all types of cements should be no more than 25 microns.

Typically, with decreasing thickness of the adhesive layer of cement bonding strength increases. There are attempts to explain the dependence of the adhesion strength of the cement film thickness influence of the solid surface, resulting in the likelihood of deformation of a thin layer of cement is less than thick.

With the increase of the cement layer thickness increases volumetric polymerization shrinkage inherent in all composite materials, which is one of the causes of violations of marginal adaptation cemented structure.

Thus, the film thickness is an important factor in determining the ability of a sealing cement, adhesive bond strength, functional and aesthetic properties of the prosthetic tamperproof ceramics.

Also taken into account the working time after mixing self-curing cement components - a time interval during which the cooked mass may be manipulated prior to hardening and the appearance of the risk of incomplete installation of the prosthesis.

In operation, the fixed denture in the oral cavity by the chewing action of the load most of the cement film is subjected to compression, so the cement compression strength (compression strength) has a significant impact on the longevity and durability of adhesive joint.

Along with the physical and chemical properties of cements important value for a secure fit of the prosthesis has the quality of their relationship with the firm support of the tooth tissues.

In the clinic of orthopedic dentistry frequent violations of permanent fixation of fixed prosthesis in the form of so-called rastsementirovok. This may be due to many reasons, including, first of all, it should be called a breach of fit and the development of caries process after fixing the fixed prosthesis.

Thus, the choice of material for the fixation depends on the following factors:

1. The degree of preparation of a tooth stump;

2. The shape of the cavity or stump;

3. The type of construction;

4. The quality of design processing;

5. The degree of isolation of the abutment teeth.

Alcohol and ether is not used for processing. Ether gave rapid cooling of the tooth increases and consequently flow of dentinal fluid out of the channels. The alcohol and ester form a film on the tooth surface, complicating the fixing material compound (GIC and especially the polymer-based cement). In addition, alcohol and ether in a suitable concentration affect the oral mucosa. Chance of necrosis after administration of these drugs.

Conclusion

After analyzing the current literature on the subject, we have come to the conclusion that there are quite a number of reasons contributing to a breach of prosthetic fixation. A certain percentage of failures is inevitable in any way, but their number can also be minimized. Important factors that affect the result of the work is high quality preparation of the tooth, adequate insulation, the correct selection and use of fixing material.



References:
1. Danilina TF, Fomina TK, Kolesova TV , Naumova VN, Derevyanchenko SP, Denisenko LN, Zhidovinov AV Interdepartmental integration as the instrument of development by foreign students of professional skills on dentistry/ Modern problems of science and education. - 2015. - № 4. - P. 286.

2. Danilina TF, Mihalchenko DV, Zhidovinov AV, Virabyan VA Effect of immune inflammation on the development of halvanosis symptoms in the mouth/Volgograd scientific and medical journal . - 2014. - № 1. - P. 47-49.

3. Firsova I.V., Makedonova Iu.A., Mikhalchenko D.V., Poroiskii S.V., Sirak S.V. Сlinical and experimental study of the regenerative features of oral mucosa under autohemotherapy//Research Journal of Pharmaceutical, Biological and Chemical Sciences. 2015. Т. 6. № 6. P. 1711-1716.

4. Mihalchenko DV, Danilina TF, Verstakov DV Denture teeth with low crowns fixed bridge/ Fundamental research. - 2013. - №. 9-6. – P.1066-1069.

5. Mihalchenko DV, Mihalchenko AV, Zhidovinov AV, Naumov VN Need for further education of healthcare professionals on doctor -patient relationship/Volgograd scientific and medical journal. - 2014. - № 2. - P. 41-44.

6. Mihalchenko DV, Mihalchenko VF, Manuylova EV, Zhidovinov AV, Filyuk EA The rationale for the use of calcium-containing preparations in the treatment of chronic apical periodontitis according to the results of immunological studies/Modern problems of science and education. - 2014. - № 6. - P. 1019.

7. Mihalchenko DV, Zhidovinov AV, Arutyunov GR, Efremyan GM, Golovchenko SG Comparative evaluation retraction gels in prosthesis fixed prosthetic constructions/Modern problems of science and education. - 2015. - № 3. - P. 229.

8. Mihalchenko VF, Mihalchenko AV, Antipova OA, Fedotova YM, Zhidovinov AV Efficiency of application of material photoactivated disinfection and «calcicur» the treatment of deep caries/Modern problems of science and education. - 2015. - № 1-1. - P. 1287.

9. Milikevich VY, Klauchek SV, Mihalchenko DV Psychophysiological aspects of human adaptation to the prediction of orthopedic dental treatment/Dentistry. - 1998. - V. 77. - № 6. - P. 61-62.

10. Zhidovinov AV Research of local adaptive reactions of radiotherapy patients with defects of maxillofacial prosthesis removable/Modern problems of science and education. - 2015. - № 6-0. - P. 60.



Bibliographic reference

Mihalchenko D.V., Sirak S.V., Zhidovinov A.V., Matveev S.V. REASONS FOR BREACH OF FIXING NON-REMOVABLE DENTURES. International Journal Of Applied And Fundamental Research. – 2016. – № 5 –
URL: www.science-sd.com/467-25067 (20.04.2024).